The valve is a counterbalance valve with control and backflow
prevention.
• If the load starts to run away, the control signal decreases and
the valve closes. The counterbalance spool maintains a position
that keeps the control signal positive and regulates the load
lowering.
• The valve is used in applications where smooth
operation and almost no cylinder leakage are required.
• The valve prevents cavitation of the actuator and ensures positive
control under overloads.
• Control valves must not be subjected to backpressure, because
this affects performance and may cause instability
in operation.
• Standard setting 320bar
• Setting 80bar/rev
| Code | Opening ratio | Max. working press. (bar) | Internal thrd. (BSP) | Max. flow rate (l/min) | Package size (KPL) | 3D |
|---|---|---|---|---|---|---|
| KLVS-08 | 1 : 3,1 | 350 | 1/2” | 50 | 1 |