Double overcentre valve

Double overcentre valve
Double overcentre valve

Double-acting counterbalance valve can be used e.g. for holding a boom in position and for smooth lowering. The second working port does not open until the pilot pressure of the first port rises above the set minimum value.

  • V1 and V2 are connected to the pressure lines
  • C1 and C2 are connected to the lines going to the actuator
  • max load pressure 245bar
  • standard adjustment by spring 320bar
  • adjustment 80bar/turn
  • The valve pressure setting must be at least 1.3 times higher than the load pressure, so that the valve can close even when the load pressure is at its highest
  • Oleodinamica marchesini VBCD DE
CodeInternal thrd. (BSP)Control ratioMax. working press. (bar)Max. flow rate (l/min)Manufacturer modelManufacturer codeDiagramPackage size (KPL)3D
KLV-123/4"1:5,5350105VBCD ¾” DEV0431DXF1