FR3S. The valve can be used to electrically control a regulated flow, e.g. to a hydraulic hammer, while diverting part of the flow to control cylinders and other actuators. For open-centre systems.
When the cartridge valve is open (in its normal position), the flow coming to line IN is directed to line B.
When the cartridge valve is energized (the valve closes), the flow is split to the hammer in line P and to other actuators in line B. Devices connected to line B are functions related to the normal operation of the machine, such as cylinder movements.
NOTE!! THE HAMMER LINE OF THE HAMMER VALVE REQUIRES CHECK VALVE FR3S-FPR TO OBTAIN THE REQUIRED BACK PRESSURE.
| Code | Threads (BSP) | Max inlet flow (l/min) | Max adjusted flow (l/min) | Factory setting (l/min) | Flow increase/revolution (l/min) | Package size (KPL) |
|---|---|---|---|---|---|---|
| FR3S-08-350NO | 1/2" | 100 | 85 | 30 | 18 | 1 |
| FR3S-12-350NO | 3/4" | 200 | 140 | 30 | 20 | 1 |
| FR3S-16-350NO | 1" | 300 | 220 | 30 | 26 | 1 |
| FR3S-20-350NO | 1 1/4" | 400 | 300 | 30 | 28 | 1 |