The lever locks when pushed and returns to the neutral position when the mechanical stop presses the knob at the end of the valve lever cup, usually when the cylinder has reached its end position When the lever is pulled slightly, quick mode is selected, in which oil returning from the cylinder on the rod side is routed directly back to the piston side to speed up the movement If more splitting force is needed, the lever is pulled fully to the force position, in which the oil returning from the cylinder is routed to the tank and the cylinder movement slows down, while the splitting force increases • Quick mode cannot be used during the return stroke • Maximum pressure 250bar at port P • Maximum pressure in lines A and B 300bar • Maximum tank line pressure 50bar
| Code | Adjust. range (bar) | Max. flow rate (l/min) | Working ports (BSP) | Pressure and return ports (BSP) | Main safety valve (bar) | Package size (KPL) |
|---|---|---|---|---|---|---|
| V81KLPL-MEK | 70-140 | 80 | 1/2” | 3/4” | 160 | 1 |