Solenoid valve Festo VUVS-LK, bistable

Product also in categories: Electrically operated valves
Solenoid valve Festo VUVS-LK, bistable

A bistable valve changes position with a short electrical pulse and holds its position even after the voltage is removed. Solenoids are fitted at both ends of the body: one switches to the position, the other switches back. This differs from a monostable model, which returns to its initial position by spring as soon as the voltage is removed.

When to choose bistable

  • The cylinder position must not change during a power failure
  • Control by pulse instead of continuous voltage — saves energy
  • Two separate control signals (e.g. up/down from different outputs)

Safety note: a bistable valve does not return the cylinder to a safe position when the voltage is removed. If the application requires a return, select a monostable model.

VUVS-LK series

The ports are integrated in the valve body — no separate sub-base is required. In the type code B52 denotes a bistable 5/2 valve and +GL means the connector is included.

Technical data

  • Operating pressure 1.5–8 bar
  • Operating voltage 24 V DC, ±10 %
  • Degree of protection IP65 (with plug socket, IEC 60529)
  • Media and ambient temperature −5…+50 °C
  • Body and piston slide in wrought aluminium alloy, seals HNBR/NBR
  • Manual override: detenting and non-detenting
  • Any mounting position, internal pilot air supply
  • Compressed air to ISO 8573-1:2010 [7:4:4], lubricated operation possible
  • RoHS compliant
CodeManufacturer's typePorts (BSP)CoilFlow (l/min)DiagramPackage size (KPL)
FE-8043215VUVS-LK20-B52-D-G18-1C1-SG 1/8"24 VDC550DXF1
FE-8060301VUVS-LK20-B52-D-G18-1C1+GL-SG 1/8"24 VDC + pistoke550DXF1
FE-8043219VUVS-LK25-B52-D-G14-1B2-SG 1/4"24 VDC1000DXF1
FE-8060306VUVS-LK25-B52-D-G14-1B2+GL-SG 1/4"24 VDC + pistoke1000DXF1
FE-8060311VUVS-LK30-B52-D-G38-1B2+GL-SG 3/8"24 VDC + pistoke1600DXF1